Review



10-hole titanium distal femoral locking compression plate df-lcp  (Synthes Ltd)

 
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 90

    Structured Review

    Synthes Ltd 10-hole titanium distal femoral locking compression plate df-lcp
    10 Hole Titanium Distal Femoral Locking Compression Plate Df Lcp, supplied by Synthes Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/titanium+locking+plate/8+hole++3+5+mm+locking+plate/pm40614583-83-18-26
    Average 90 stars, based on 1 article reviews
    10-hole titanium distal femoral locking compression plate df-lcp - by Bioz Stars, 2026-09
    90/100 stars

    Images

    Related Articles

    other:

    Article Title: Regenerating mandibular bone using rhBMP-2: part 1 - immediate reconstruction of segmental mandibulectomies
    Article Snippet: 33 Following measurements and marking of the resection area , a single titanium locking plate (3.0 mm, Synthes ® Maxillofacial, Paoli, PA) was contoured prior to the amputation, capturing the normal anatomic contour of the ventrolateral mandible.

    Article Title: PEEK versus titanium locking plates for proximal humerus fracture fixation: a comparative biomechanical study in two- and three-part fractures.
    Article Snippet: Introduction The high rigidity of metal implants may be a cause of failure after fixation of proximal humerus fractures.. Carbon fiber-reinforced polyetheretherketone (PEEK) plates with a modulus similar to human cortical bone may help to overcome this problem.. The present study assesses the biomechanical behavior of a PEEK plate compared with a titanium locking plate.

    Article Title: An Unusual Deadly Craniofacial Trauma Case Due To Hot Liquid Plastic Infusion
    Article Snippet: remains controversial.. Some studies demonstrated that chemotherapy contributes to long-term survival, whereas others have not shown any benefit.. Owing to their rarity, there is currently no established protocol for the treatment of CPC.

    Article Title: Osteomas involving the facial skeleton: a report of 2 cases and review of the literature.
    Article Snippet: Osteomas are benign slow-growing tumors.. These lesions are essentially restricted to the craniofacial skeleton and rarely diagnosed in other bones.. The etiology is often multifactorial.



    Similar Products

    86
    Stryker variax dorsal distal titanium alloy locking implant plate
    Variax Dorsal Distal Titanium Alloy Locking Implant Plate, supplied by Stryker, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/titanium+locking+plate/plating+stryker+system/pm41185401-72-21-20
    Average 86 stars, based on 1 article reviews
    variax dorsal distal titanium alloy locking implant plate - by Bioz Stars, 2026-09
    86/100 stars
      Buy from Supplier

    90
    Synthes Ltd 10-hole titanium distal femoral locking compression plate df-lcp
    10 Hole Titanium Distal Femoral Locking Compression Plate Df Lcp, supplied by Synthes Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/titanium+locking+plate/8+hole++3+5+mm+locking+plate/pm40614583-83-18-26
    Average 90 stars, based on 1 article reviews
    10-hole titanium distal femoral locking compression plate df-lcp - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    90
    DePuy Synthes locking plate osteosynthesis 4.5/5.0 lcp, narrow, 6-hole, titanium 424.561
    Oblique fracture at the distal tibia stabilized by plate <t>osteosynthesis</t> and supplemental cable cerclage wiring in human bone ( a ) and custom-made synthetic bone ( b ). Test setup with two cardan joints to reduce constraint forces ( c )
    Locking Plate Osteosynthesis 4.5/5.0 Lcp, Narrow, 6 Hole, Titanium 424.561, supplied by DePuy Synthes, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/titanium+locking+plate/12+hole+lcp/pmc12159113-44-2-10
    Average 90 stars, based on 1 article reviews
    locking plate osteosynthesis 4.5/5.0 lcp, narrow, 6-hole, titanium 424.561 - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    90
    Zimmer Biomet zimmer biomet a.l.p.s. distal femur titanium lateral locking plate
    Oblique fracture at the distal tibia stabilized by plate <t>osteosynthesis</t> and supplemental cable cerclage wiring in human bone ( a ) and custom-made synthetic bone ( b ). Test setup with two cardan joints to reduce constraint forces ( c )
    Zimmer Biomet A.L.P.S. Distal Femur Titanium Lateral Locking Plate, supplied by Zimmer Biomet, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/titanium+locking+plate/periarticular+plate/pmc12122169-83-35-42
    Average 90 stars, based on 1 article reviews
    zimmer biomet a.l.p.s. distal femur titanium lateral locking plate - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    90
    Synthes Ltd locking titanium plates matrixrib/synthes cmf
    Oblique fracture at the distal tibia stabilized by plate <t>osteosynthesis</t> and supplemental cable cerclage wiring in human bone ( a ) and custom-made synthetic bone ( b ). Test setup with two cardan joints to reduce constraint forces ( c )
    Locking Titanium Plates Matrixrib/Synthes Cmf, supplied by Synthes Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/titanium+locking+plate/locking+titanium+plates+matrixrib+synthes+cmf/pmc12066399-18-7-9
    Average 90 stars, based on 1 article reviews
    locking titanium plates matrixrib/synthes cmf - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    90
    DePuy Synthes human titanium locking compression plate
    Oblique fracture at the distal tibia stabilized by plate <t>osteosynthesis</t> and supplemental cable cerclage wiring in human bone ( a ) and custom-made synthetic bone ( b ). Test setup with two cardan joints to reduce constraint forces ( c )
    Human Titanium Locking Compression Plate, supplied by DePuy Synthes, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/titanium+locking+plate/titanium+lcp+reconstruction+plate/pm40220497-65-7-17
    Average 90 stars, based on 1 article reviews
    human titanium locking compression plate - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    90
    Beijing Fule Science Technology Development Co Ltd straight reconstruction locking titanium alloy plate, 8 holes
    Oblique fracture at the distal tibia stabilized by plate <t>osteosynthesis</t> and supplemental cable cerclage wiring in human bone ( a ) and custom-made synthetic bone ( b ). Test setup with two cardan joints to reduce constraint forces ( c )
    Straight Reconstruction Locking Titanium Alloy Plate, 8 Holes, supplied by Beijing Fule Science Technology Development Co Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/titanium+locking+plate/straight+reconstruction+locking+titanium+alloy+plate++8+holes/pm40064992-79-1-14
    Average 90 stars, based on 1 article reviews
    straight reconstruction locking titanium alloy plate, 8 holes - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    90
    Synthes Ltd lcptm synthes titanium locking plate
    Oblique fracture at the distal tibia stabilized by plate <t>osteosynthesis</t> and supplemental cable cerclage wiring in human bone ( a ) and custom-made synthetic bone ( b ). Test setup with two cardan joints to reduce constraint forces ( c )
    Lcptm Synthes Titanium Locking Plate, supplied by Synthes Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/titanium+locking+plate/titanium+locking+plate/pm39069349-57-1-2
    Average 90 stars, based on 1 article reviews
    lcptm synthes titanium locking plate - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    90
    DePuy Synthes titanium locking plate tomofix
    Oblique fracture at the distal tibia stabilized by plate <t>osteosynthesis</t> and supplemental cable cerclage wiring in human bone ( a ) and custom-made synthetic bone ( b ). Test setup with two cardan joints to reduce constraint forces ( c )
    Titanium Locking Plate Tomofix, supplied by DePuy Synthes, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/titanium+locking+plate/titanium+rocking+plate+tomofix/pm39069022-57-37-41
    Average 90 stars, based on 1 article reviews
    titanium locking plate tomofix - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    Image Search Results


    Oblique fracture at the distal tibia stabilized by plate osteosynthesis and supplemental cable cerclage wiring in human bone ( a ) and custom-made synthetic bone ( b ). Test setup with two cardan joints to reduce constraint forces ( c )

    Journal: European Journal of Trauma and Emergency Surgery

    Article Title: Biomechanical evaluation of cerclage wiring in plated tibia fractures using human and synthetic specimens

    doi: 10.1007/s00068-025-02894-8

    Figure Lengend Snippet: Oblique fracture at the distal tibia stabilized by plate osteosynthesis and supplemental cable cerclage wiring in human bone ( a ) and custom-made synthetic bone ( b ). Test setup with two cardan joints to reduce constraint forces ( c )

    Article Snippet: Finally, locking plate osteosynthesis (4.5/5.0 LCP, narrow, 6-hole, Titanium 424.561, DePuy Synthes, Johnson & Johnson) with two screws per fragment was applied and tightened at 4 Nm (Fig. ).

    Techniques: